Karakterisasi Limbah Cair Rumah Pemotongan Hewan Pesanggaran

I Wayan Suardana

Abstract


This research aimed to analyze the ability of wastewater treatment to reduce the pollutant component at the
wastewater that produced by slaughtered activities, so that the hazards that impacted by the activities to the community that
lived surrounding the area can be monitoring. This experiment used Randomize Completely Block Design, with 5 point
collected samples as block and 5 times repeatly as treatment. Result of the research at 50 meters from the end of wastewater
treatment to generally sewage for the temperature parameter (26.40 + 0.42 0C), pH (6.97 + 0.11), BOD5 (124.200 + 8.352
mg/l) and COD (255.000 + 20.07 mg/l) indicated equal with the standard. The result means the wastewater management at
Pesanggaran slaughterhouse is effective to produce wastewater quality with the second standard (waste water standard for
agriculture) of wastewater quality according to the Indonesian National Standard.

Keywords


Slaughterhouse, temperature, pH, BOD5, COD